I.P.C LABORATORY 


COMPUTERIZED CASCADE CONTROL SYSTEM

 

 

 

 

IPC-001  CALIBRATION OF VENTURIMETER, ORIFICEMETER &     

                ROTAMETER

                        The Setup Consists of :
a. Orificemeter : 1“ size with two G.M. Clocks.
b. Venturimeter : 1“ size with two G.M. Clocks.
c. Rotameter : 1“ size with 4.2 - 42 LPM.
d. Water Sump : 150 Ltr Capacity for close circuit system.
e. Measuring Tank : 300 x  300 x 450 mm size with drain valve &
    gauge glass fittings.
f.    Manometer : 1 mtr. height differential manometer without mercury.
g.   Water pump : ½ HP for water circulation.
h.   Instruction Manual : 1 Copy.

ICP-002  MEASUREMENT OF LEVEL BY AIR PURGE METHOD.             

                        The setup consists of :
a.   Air Purging Valve  : ¼ “  BSP.
b.   Manometer : 0.3 mtr. height.
c.   Water tank of glass fitted in M.S. Casing.
d.   Copper Tubing.
The whole unit is mounted on sturdy M.S. Frame.

IPC-003  DETERMINATION OF TIME CONSTANT OF THERMOMETER. 

                        This setup consists of :
a.   Digital Temperature Indicator with thermocouple.
b.   Mercury filled dial thermometer.
c.   Vapour pressure thermometer.
d.   Electric sergri with pot.
e.   Ice pot.
f.    Instruction Manual : 1 Copy

IPC-004  DETERMINATION OF TIME CONSTANT OF MANOMETER         

                        The setup consists of :
a.   Three manometers of different tubes & different height with different
     manometric fluid in each.
b.   M.S. Structure with board for mounting of three manometers.
c.   Air pressure regulator : 1 No.
d.   Instruction Manual :  1 Copy.

* Service Required *

Constant air supply of compressor @ 1 CFM & pressure @ 2 - 3 Kg/Cm2.

IPC-005  CALIBRATION OF BIMETALLIC THERMOMETER

                        The Setup consists of :
a.   Bimetallic Thermometer :  0 - 100 oC.
b.   Constant Temperature bath with electrically heating element.
c.   Ice pot : 1 No.
d.   Glass Thermometer :  1 No.
e.   Instruction Manual : 1 Copy.

IPC-006  THERMOCOUPLE CALIBRATION TEST RIG

                        The setup consists of :
a.   Three different types of thermocouples, i.e. CR/AL, Cu-Constant & Fe-Constant.
b.   Constant temperature bath with heating element for hot junction.
c.   Glass Thermometer : 1 No.
d.   Instruction Manual : 1 No.

IPC-007  DEAD WEIGHT PRESSURE GAUGE TESTER

                        Range available : 0 - 30 Kg/Cm2  , 40 Kg/Cm2  , 60 Kg/Cm2.  Tester provided with
a gauge connector of ½ “ BSP of complete with one set of weights in a storage box.
One dust cover, spanner & one set of spare seals.

IPC-008  DEAD WEIGHT VACUUM GAUGE TESTER

                        Range : 0 - 740 mm of Hg.
Tester provided with one set of weights a storage box, gauge connector of ½
“ BSP One dust cover, Instruction Manual one Pointer Puller, a adapter of
M20 x ¼”,  ½ “ & 3/8” BSP, four  spanner & one set of spare seals.

IPC-009  DIGITAL PH METER                                                                 

                        The PH meter with test probes, stand & breaker.

IPC-010  PERFORMANCE OF PNEUMATIC PI CONTROLLER.                   

                        The Setup Consists of :

                  A.   Control Panel
a. Pneumatic PI Controller :
    Input                :           0 - 10 Kg/Cm2.
    Output             :           0.2 - 1.2 Kg/Cm2.
    Air Supply        :           2 Kg/Cm2.
    Mounting          :           Panel Mounting.
b. Air Filter Regulator :
    Input                :           0 - 10 Kg/Cm2.
    Output             :           0.2 - 1.2 Kg/Cm2.
    Filter                :           Bronze.

                   B.  Final Control Element :
a. Pneumatically Actuated Diaphragm Control Valve :
    Size                 :           15 mm.
    Action              :           Air to Open.
    Seat & Plug     :           SS-316.
    Qty.                 :           1 No.
b. Air Vessel :
    Capacity                      :           20 Ltr.
    Design Pressure         :           30 Kg/Cm2.
    Instruction Manual       :           1 Copy

* Service Required *

Constant air @ 6 CFM & pressure @ 4 Kg/Cm2.

 

IPC-011          CHARACTERISTICS OF CONTROL VALVE.                                  

                  ( Equal & Linear Percentage )
The Setup Consists of :
a. Pneumatically actuated diaphragm Control valve :
Size : 25 mm.
Action : Air to  Open.
Seat & Plug : SS-316
Type : Equal Percentage : 1 No.
            Linear Percentage : 1 No.
b. Air Filter Regulator :
    Input                :           0 - 10 Kg/Cm2.
   Output             :           0.2 - 1.2 Kg/Cm2.
   Filter                :           Bronze. 
c. Measuring Tank :
Size : 300 x  300 x 450 mm with drain valve & gauge glass fittings & a scale .
d. Supply Tank : Capacity : 150 Ltr with drain plug.
e. Water Pump : Capacity : ½” HP Single Phase for water circulation
f. Instruction Manual : 1 Copy.

                   * Service Required *
Constant air @ 6 CFM & pressure @ 2 Kg/Cm2.

IPC-012  COMPUTERISED PH CONTROL SYSTEM.                                

                        The Setup consists of :

A.   Control Panel :

a.
Computer : Pentium with 8 MB RAM.
                     :           1.44 MB FDD.
                     :           101 Keys Keyboard.
                     :           Super VGA color Monitor.
b. ADC Card                   :           1 No.
c. DAC Card                   :           1 No.
d. I/P Converter   :
    Input                            :           4 - 20 mA.
    Output                         :           0.2 - 1 Kg/ Cm2.
e. Allarm Annunciator      :           Built to Computer.
f. Hooter                         :           Built to Computer.
g. Air Filter Regulator      :
     Input                            :           0 - 10 Kg/Cm2.
     Output                         :           0.2 - 1.2 Kg/Cm2.
h. Control Panel :
It is fabricated from 16 gauge CRC sheet & well epoxy coated. All the above
instruments & wring will be mounted on panel.  All the connections & wring will be
inside the panel.  Necessary switches, indicators are mounted on the panel.

                  B.  Control Software :

                        A powerful control software Window 98 Based for PH control.  On/Off control, proportional control, proportional plus integral control, proportional plus integral plus derivative  are done by software.

                        Simulating various patterns of process variables & studying the controller response.

                  C.  PH Transmission & Final Control Element :

                        a. Electronic PH Transmitter :
    Input                            :           From test probes.
   Output                         :           4 - 20 mA.
b. Pneumatically Actuated Diaphragm Control Valve.
    Size                             :           15 mm.
   Action                          :           Air to Open.
   Seat & Plug                 :           SS-316
   Type                            :           Linear Percentage.
c. Rotameter                   :           1 - 11 LPM for water.
d. Chemical Tank            :           100 Ltr. capacity.
e. Instruction Manual       :           1 Copy

IPC-013             TWO TANK SYSTEM

                  A.   INTERACTING SYSTEM.                                                                              

                        The Unit Consists of :
a. Water Tank     :           250 x 300 600 mm  - 1 Nos.
b. Water Sump   :           250 x 300 x 600 mm -  1 No.
c.
Water Pump   :           Capacity  : ½ H. P. for water circulation.
d. Strong iron stand for supporting the equipment.
e.
Above two tanks are mounted in such a manner that system will be intractor.
f. Gauge glass fitting scale with drain valve will be provided to each tank.
g. Instruction Manual :  1 Copy.

                  B.  NON-INTERACTING SYSTEM

                        Same as above ( A ), but two tanks are mounted in such a manner that system will be Non-Interaction.

IPC-014  CLOSED LOOP FLOW CONTROL SYSTEM

                        The setup consists of :

                  A.   Control Panel :
a. PID Controller             :           ( Electronic )
    Input                            :           4 - 20 mA.
    Output                         :           4 - 20 mA.
    Display                        :           3.5 Digit.
    Proportional Band       :           2 - 500 %.
    Integral Action :           0.05 - 50 R/min.
    Derivative Action         :           0.01 - 10 Min.
b. I/P Converter   :
    Input                            :           4 - 20 mA.
   Output                         :           0.2 - 1 Kg/ Cm2.
c. Alarm Annunciator      :           4 Window.
d. Hooter                         :           1 No.
e. Air Filter Regulator      :
    Input                            :           0 - 10 Kg/Cm2.
    Output                         :           0.2 - 1.2 Kg/Cm2.
f. Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated.
   All the above instruments & wring will be mounted on panel.  All the connections
   & wring will be inside the panel.  Necessary switches, indicators are mounted on
   the panel.

                  B.  Flow Transmission & Final Control Element :

                  a.   Flow Transmitter ( Wheel Type Electronic )
Range             :           4.2 - 42 LPM.
Output             :           4 - 20 mA.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air to Open.
Seat & Plug     :           SS-316.
Type                :           Linear Percentage : 1 No. 

                  c.   Rotameter       :
Range             :           4.2 - 42 LPM.
Service            :           Water.

                  d.   Collecting Tank :
Size : 300 x  300 x 450 mm with drain valve & gauge glass fittings & a scale .

                  e.   Water Sump   :           150 Ltr . Capacity  with drain plug

                  f.    Water Pump : Capacity : ½” HP Single Phase for water circulation

                  g.   Instruction Manual : 1 Copy.

                  * Service Required * Constant air @ 6 CFM & pressure @ 2 Kg/Cm2.

IPC-015  CLOSED LOOP LEVEL CONTROL SYSTEM

                        The setup consists of :

                  A.   Control Panel :

                        a. PID Controller             :           ( Electronic )
    Input                            :           4 - 20 mA.
    Output                         :           4 - 20 mA.
    Display                        :           3.5 Digit.
    Proportional Band       :           2 - 500 %.
    Integral Action :           0.05 - 50 R/min.
    Derivative Action         :           0.01 - 10 Min.
b. I/P Converter   :
    Input                            :           4 - 20 mA.
    Output                         :           0.2 - 1 Kg/ Cm2.
c. Alarm Annunciator      :           4 Window.
d.  Hooter                         :           1 No.
e. Air Filter Regulator      :
    Input                            :           0 - 10 Kg/Cm2.
    Output                         :           0.2 - 1.2 Kg/Cm2.
f. Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated.
   All the above instruments & wring will be mounted on panel.  All the connections
   & wring will be inside the panel.  Necessary switches, indicators are mounted on
   the panel.

                  B.  Level Transmission & Final Control Element :

                  a.   Electronic Liquid Level Transmitter :
Range             :           0 - 1000 mm of  WC
Output             :           4 - 20 mA.
Supply             :           24 V DC.
Mounting          :           Field mounting type.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air to Open.
Seat & Plug     :           SS-316
Type                :           Linear Percentage : 1 No.

                  c.   Rotameter       :
Range             :           4.2 - 42 LPM.
Service            :           Water.

                  d.   Liquid Level Tank : 90 Ltr. capacity with overflow arrangement, drain valve gauge fittings & a scale

                  e    Water Sump   :           150 Ltr . Capacity  with drain plug.

                  e.   Water Pump : Capacity : ½” HP Single Phase for water circulation

                  f.    Instruction Manual : 1 Copy.

                  * Service Required * Constant air @ 6 CFM & pressure @ 3 Kg/Cm2.

IPC-016 CLOSED LOOP PRESSURE CONTROL SYSTEM

                        The setup consists of :

                  A.   Control Panel :

                        a. PID Controller             :           ( Electronic )
    Input                            :           4 - 20 mA.
    Output                         :           4 - 20 mA.
    Display                        :           3.5 Digit.
    Proportional Band       :           2 - 500 %.
    Integral Action :           0.05 - 50 R/min.
    Derivative Action         :           0.01 - 10 Min. 
b. I/P Converter   :
    Input                            :           4 - 20 mA.
    Output                         :           0.2 - 1 Kg/ Cm2.
c. Alarm Annunciator :    4 Window.
d. Hooter                         :           1 No.
e. Air Filter Regulator      :
    Input                            :           0 - 10 Kg/Cm2.
    Output                         :           0 - 2 Kg/Cm2.
f.
Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel.  All the connections
& wring will be inside the panel.  Necessary switches, indicators are mounted on
the panel.

                  B.  Pressure Transmission & Final Control Element :

                  a.   Electronic Pressure Transmitter :
Range             :           0 - 5 Kg/Cm2.
Output             :           4 - 20 mA.
Supply             :           24 V DC.
Mounting          :           Field mounting type.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air to Open.
Seat & Plug     :           SS-316.
Type                :           Linear Percentage : 1 No.

                  c.   Air Tank           : 2 Nos. with interconnecting valve pressure gauges mounted
on the tanks.

                  d.   Air Compressor : 2 HP, 3 Phase motion & Air Tank Cap. 100 Ltr.

                  e.   Instruction Manual : 1 Copy.

IPC-017  CLOSED LOOP TEMPERATURE CONTROL SYSTEM

                        The setup consists of :

                  A.   Control Panel :
a. PID Controller             :           ( Electronic )
    Input                            :           4 - 20 mA.
    Output                         :           4 - 20 mA.
    Display                        :           3.5 Digit.
    Proportional Band       :           2 - 500 %.
    Integral Action :           0.05 - 50 R/min.
    Derivative Action         :           0.01 - 10 Min.
b. I/P Converter   :
    Input                            :           4 - 20 mA.
    Output                         :           0 - 2 Kg/ Cm2.
c. Alarm Annunciator      :           4 Window.
d. Hooter                         :           1 No.
e. Air Filter Regulator      :
    Input                            :           0 - 10 Kg/Cm2.
    Output                         :           0 - 2 Kg/Cm2.
f. Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated.
   All the above instruments & wring will be mounted on panel.  All the connections
   & wring will be inside the panel.  Necessary switches, indicators are mounted on
    the panel.

                  B.  Temperature Transmission & Final Control Element :
a. Temperature Transmitter :
    Input : From RTD
    Output : 4 - 20 mA.
    Supply : 24 V DC.
    Mounting  : Field mounting type.
b. Pneumatically actuated diaphragm Control valve :
    Size : 15 mm.
    Action1  : Air to  Open.
    Seat & Plug : SS-316.
    Type : Linear Percentage : 1 No.
c.   Rotameter       :
    Range : 1.1 - 11 LPM.
    Service : Water.
d.   Heater Exchanger  :    Shell & Tube Type.
    Capacity : 150 Kg/hr.
e    Water Sump : 100 Ltr . Capacity  with drain plug &
                            4 Kw heater fitted to tank for hot water.
e.   Water Pump : Capacity : ½” HP Single Phase for hot water circulation
f.    Instruction Manual : 1 Copy. 

                  * Service Required *
Constant air @ 6 CFM & pressure @ 2 Kg/Cm2.
Cold water, @ 20 Ltr./min ( Min )

IPC-018  COMPUTERISED CLOSED LOOP FLOW CONTROL SYSTEM

                        The Setup consists of :

                  A.   Control Panel :
a. Computer : Pentium with 8 MB RAM
                    :           1.44 MB FDD.
                    :           101 Keys Keyboard.
                    :           Super VGA color Monitor.
b. ADC Card : 1 No.
c. DAC Card : 1 No.
d. I/P Converter :
    Input : 4 - 20 mA.
   Output  : 0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator     :            Built to Computer.
f. Hooter                         :           Built to Computer.
g. Air Filter Regulator      :
    Input                           :            0 - 10 Kg/Cm2.
   Output                        :            0.2 - 1.2 Kg/Cm2.
h.
Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated.
   All the above instruments & wring will be mounted on panel.  All the connections
   & wring will be inside the panel.  Necessary switches, indicators are mounted on
   the panel.

                  B.  Control Software :

                        A powerful control software Window 98 Based for flow control system. On/Off
control, proportional control, proportional plus integral control, proportional plus integral plus derivative control are done by software.

                        Simulating various patterns of process variables & studying the controller response.

                  C.  Flow Transmission & Final Control Element :

                  a.   Flow Transmitter ( Wheel Type Electronic )
Range             :           4.2 - 42 LPM.
Output             :           4 - 20 mA.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air Open.
Seat & Plug     :           SS-316.
Type                :           Linear Percentage : 1 No.

                  c.   Rotameter       :
Range             :           4.2 - 42 LPM.
Service            :           Water.

                  d.   Collecting Tank : Size : 300 x  300 x 450 mm with drain valve & gauge glass fittings
& a scale .

                  e.   Water Sump   :           150 Ltr . Capacity  with drain plug

                  f.    Water Pump : Capacity : ½” HP Single Phase for water circulation

                  g.   Instruction Manual : 1 Copy.

                  * Service Required * Constant air @ 6 CFM & pressure @ 3 Kg/Cm2.

IPC-019  COMPUTERISED CLOSED LOOP LEVEL CONTROL SYSTEM

                        The Setup consists of :

                  A.   Control Panel :

                        a. Computer :  Pentium with 8 MB RAM.
                    :           1.44 MB FDD.
                    :           101 Keys Keyboard.
                    :           Super VGA color Monitor.
b. ADC Card : 1 No.
c. DAC Card  : 1 No.
d. I/P Converter   : Input : 4 - 20 mA.
    Output : 0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator :    Built to Computer.
f.
Hooter : Built to Computer.
g. Air Filter Regulator      :
    Input                            :           0 - 10 Kg/Cm2.
   Output                         :           0 - 2 Kg/Cm2.
h. Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy
   coated.  All the above instruments & wring will be mounted on panel. All the
   connections & wring will be inside the panel.  Necessary switches, indicators are
   mounted on the panel.

                  B.  Control Software :

                        A powerful control software Window 98 Based for level control system. On/Off control, proportional control, proportional plus integral control, proportional plus integral plus derivative control are done by software.

                        Simulating various patterns of process variables & studying the controller response.

                  C.  Level Transmission & Final Control Element :

                  a.   Level Transmitter :
Range             :           0 - 1000 mm of  WC
Output             :           4 - 20 mA.
Supply             :           24 V DC.
Mounting          :           Field mounting type.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air Open.
Seat & Plug     :           SS-316.
Type                :           Linear Percentage : 1 No.

                  c.   Rotameter       :
Range             :           4.2 - 42 LPM.
Service            :           Water.

                  d.   Liquid Level Tank : 90 Ltr. capacity with overflow arrangement, drain valve gauge fittings & a scale

                  e    Water Sump   :           150 Ltr . Capacity  with drain plug. 
Capacity : ½” HP Single Phase for water circulation

                  f.    Instruction Manual : 1 Copy.

                  * Service Required *

                        Constant air @ 6 CFM & pressure @ 3 Kg/Cm2.

IPC-020  COMPUTERISED CLOSED LOOP PRESSURE CONTROL SYSTEM.

                        The Setup consists of :

                  A.   Control Panel :

                        a. Computer : Pentium with 8 MB RAM.
                    : 1.44 MB FDD.
                    : 101 Keys Keyboard.
                    : Super VGA color Monitor.
b. ADC Card : 1 No.
c. DAC Card : 1 No.
d.
I/P Converter   :
    Input : 4 - 20 mA.
   Output : 0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator :    Built to Computer
f. Hooter                         :           Built to Computer
g. Air Filter Regulator      :
   Input                            :           0 - 10 Kg/Cm2.
  Output                         :           0 - 2 Kg/Cm2.
h. Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated. 
  
All the above instruments & wring will be mounted on panel.  All the connections
  & wring will be inside the panel.  Necessary switches, indicators are mounted on
  the panel.

                  B.  Control Software :

                        A powerful control software Window 98 Based for pressure  control system.  On/Off control, proportional control, proportional plus integral control, proportional plus integral plus derivative control are done by software.

                        Simulating various patterns of process variables & studying the controller response.

                  C.  Pressure Transmission & Final Control Element :

                  a.   Pressure Transmitter :
Range             :           0 - 5 Kg/Cm2.
Output             :           4 - 20 mA.
Supply             :           24 V DC.
Mounting          :           Field mounting type.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air to  Open.
Seat & Plug     :           SS-316.
Type                :           Linear Percentage : 1 No.

                  c.   Air Tank : 2 Nos. with interconnecting valve pressure gauges mounted on the tanks.

                  d.   Air Compressor : 2 HP, 3 Phase motion & Air Tank Cap. 100 Ltr.

                  e.   Instruction Manual : 1 Copy.

                  * Service Required * Constant air @ 6 CFM & pressure @ 3 Kg/Cm2.

IPC-021  COMPUTERISED CLOSED LOOP TEMPERATURE CONTROL SYSTEM.

                        The Setup consists of :

                  A.   Control Panel :
a. Computer : Pentium with 8 MB RAM.
                    :           1.44 MB FDD.
                    :           101 Keys Keyboard.
                    :           Super VGA color Monitor.
b. ADC Card                   :           1 No.
c. DAC Card                   :           1 No.
d. I/P Converter               :
    Input                            :           4 - 20 mA.
    Output                         :           0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator      :           Built to Computer.
f. Hooter                         :           Built to Computer.
g. Air Filter Regulator      :
   Input : 0 - 10 Kg/Cm2.
  Output : 0 - 2 Kg/Cm2.
h. Control Panel : It is fabricated from 16 gauge CRC sheet & well epoxy coated.
   All the above instruments & wring will be mounted on panel.  All the connections
   & wring will be inside the panel.  Necessary switches, indicators are mounted on
   the panel.

                  B.  Control Software :

                        A powerful control software Window 98 Based for Temperature control. On/Off control, proportional control, proportional plus integral control, proportional plus integral plus derivative control are done by software.

                        Simulating various patterns of process variables & studying the controller response.

                  C.  Temperature Transmission & Final Control Element :

                  a.   Temperature Transmitter :
Input                :           From RTD
Output             :           4 - 20 mA.
Supply             :           24 V DC.
Mounting          :           Field mounting type.

                  b    Pneumatically actuated diaphragm Control valve :
Size                 :           15 mm.
Action              :           Air to Open.
Seat & Plug     :           SS-316.
Type                :           Linear Percentage : 1 No.

                  c.   Rotameter       :
Range             :           1.1 - 11 LPM.
Service            :           Water.

                  d.   Heater Exchanger  :    Shell & Tube Type.
Capacity          :           150 Kg/hr.

                  e    Water Sump   :           100 Ltr . Capacity  with drain plug &
                                   4 Kw heater fitted to tank for hot water.

                  e.   Water Pump : Capacity : ½” HP Single Phase for hot water circulation

                  f.    Instruction Manual : 1 Copy.

                  * Service Required *
Constant air @ 6 CFM & pressure @ 2 Kg/Cm2. Cold water, @ 20 Ltr./min ( Min )

IPC-022  COMPUTERSIED RATIO CONTROL SYSTEM.

( Based On Flow )
The System Consists of :

                  a.   Computer : Pentuim III 1.66 MHz  speed with 1.44 MB FDD, Keyboard, & Colour Monitor.

                  b.   Software : A Powerful software for ratio control system with PID controller its P,I, P+I, P+D, & PID actions.  Dataaquision for the on-line process.

                  c.   Transmitters   : Flow Transmitters : 2 Nos.
Output : 4 - 20 mA.
Supply : 24 V DC.
Range             : 0 - 500 mm of wc.

                  d.   ADC & DAC Card : 2 Nos. in built in PC.

                  e.   Level Tank       : 1 No.

                  f.    I/P Converter :  1 No.
Input                : 4 - 20 mA
Output             : 0.2 - 1 Kg/Cm2 .

                  g.   Control Valve :
Diaphragm Actuated : 1 No.
Control Valve : 
Line Size         : ½ “ 
Pressure         : 0.2 - 1 Kg/Cm2.
Action  : Air to Open.

                  h.   Alarm Annunicator : Built In PC

                  I.    Hooter : Built in PC.

                  j.    Air Filter Cum Regulator : 1 No.

                  * Service Required *
* 230 V AC Supply.
* Air at the range of 2 Kg/Cm2 constantly.

                  OPTIONAL :
i.    Printer :  EPSON LQ-1070+
 

IPC-023  COMPUTERSIED SPLIT RANGE CONTROL SYSTEM.

( Based On Temperature )
The System Consists of :
a. Computer : Pentuim 1.66 MHz  speed with 1.2 MB FDD, Keyboard, &
    Colour Monitor.
b. Software : A Powerful software for Split Range control system which is highly
    sophisticated & can be handle by any person. It includes all action of PID
    controller graphic for set point controller output & process variable.  Bar graph
    shows columns for PV, CO, Error, Percentage Deviation & set point limits.
c. Temperature Transmitters: 3 Nos.
   Output : 4 - 20 mA.
   Supply : 24 V DC.
   Range             : 0 - 200 oC.
   Input                : From PT-100 Sensor.
d. ADC & DAC Card : 2 Nos. in built in PC.
e. I/P Converter :  1 No.
   Input                : 4 - 20 mA
  Output             : 0.2 - 1 Kg/Cm2  
f. Control Valve :
   Diaphragm Actuated : 1 No.
   Control Valve : 
   Line Size         : ½ “ 
   Pressure         : 0.2 - 1 Kg/Cm2.
   Action  : Air to Open.
g.   Jacketed Vessel : 1 No.
Jacketed   Vessel   provided   with   stirrer   fitted   with   two  transmitters 
& one control valve.

                  * Service Required *
* 230 V AC Supply.
* Air at the range of 2 Kg/Cm2 constantly.

                  OPTIONAL :
i.    Printer :  EPSON LQ-1070+
  

IPC-024  COMPUTERSIED CASCADE CONTROL SYSTEM.

( Based On Level & Flow )
The System Consists of :

                  a.   Computer : Pentuim 1.66 MHz  speed with 1.2 MB FDD, Keyboard, & Colour Monitor.

                  b.   Software : A Powerful software for cascade control system with PID controller its P,I, P+I, P+D, & PID actions.  Dataquision for the on-line process.

                  c.   Flow Transmitter :
Output : 4 - 20 mA.
Supply : 24 V DC.
Range             : 0 - 500 mm of wc.

                  d.   Level Transmitter :
Output : 4 - 20 mA.
Supply : 24 V DC.
Range             : 0 - 500 mm of wc.

                  e.   ADC & DAC Card : 2 Nos. in built in PC.

                  f.    Level Tank       : 1 No.

                  g.   I/P Converter :  1 No.
Input                : 4 - 20 mA
Output             : 0.2 - 1 Kg/Cm2 .

                  h.   Control Valve :
Diaphragm Actuated : 1 No.
Control Valve 
Line Size         : ½ “ 
Pressure         : 0.2 - 1 Kg/Cm2.
Action              : Air to Open.

                  i.    Alarm Annunicator : Built In PC

                  j.    Hooter : Built in PC.

                  k.   Air Filter Cum Regulator : 1 No.

                  * Service Required *
* 230 V AC Supply.
* Air at the range of 2 Kg/Cm2  constantly.

                  OPTIONAL : 
i.    Printer :  EPSON LQ-1070+

IPC-025       CALIBRATION OF PNEUMATIC DP TRANSMITTER


                        The unit consists of ,
                          a. Pneumatic DP Transmitter -  1 No.
    
                          Range : 2500   to   5000  mm of uc
    
                          Output  :  3 to  15  PSI
    
                          Input : From differential pressure 
     
                         Air Supply : 2  Kg/cm2
                          b.   BP  Apparatus to built the pressure  
                          c.   Pressure gauge :     1 No.
                          d.   Air Filter Regulator  :     1 No.
                          e.   Control Panel for : mounting of all above items.

IPC-026       CALIBRATION OF PNEUMATIC DP TRANSMITTER              

                        The unit consists of ,
                        a. Pneumatic DP Transmitter -  1 No.
                            Range : 2500   to   5000  mm of uc

   
                        Output : 3 to  15  PSI
                            Input : From differential pressure 
                           Air Supply : 2  Kg/cm
2
                        b. BP  Apparatus to built the pressure  
                        c. Pressure gauge : 1 No.
                        d. Air Filter Regulator : 1 No.
                        e. Control Panel for : mounting of all above items.
 

IPC-027       CALIBRATION OF I/P CONVERTER

The unit consist of ,
a. I/P Converter : 1 No
    Input : 4 to 20 mA.
   Output : 2 to 1 kgl cm2  or 3 to 15 PSI
   Supply : 24 V. D. C.
b. Digital Multimeter : To measure current of I/P converter 
c. 4-20 mA. Current sourct :    For 4 to 20 mA. Input to converter
d. 24 V. D.  C. Power supply :   1 No.
e. Pressure Gauge : o to 1 kg cm2 to measure output signal from converter.
f. Control Panel : For mounting all above instruments.

IPC-028 CALIBRATION  OF P/I  CONVERTOR

                                    The setup consists of 
                                    a.                Pressure to current converter 
                                    Input  : 3  to 15
                                    Out put : 4 mA  to  20 mA.
                                    b. Air filter regulator   1  No
                                    c. Digital current indicator   1 No
                                    d. 24 V Dc constant current power supply 1 No
                                    e.
Instruction manual  1  No.

IPC-029                EXPERIMENTAL SET UP OF V/F  CONVERTER                     

                                    The setup consists of :
                                    a.                  Voltage to frequency converter
                                    Input  :  0-230  V
                                    Out put  :  0-50  Hz 
                                    b. Driver card  1  No.
                                    c. Voltmeter   1 No
                                    d.
Frequency meter  1  No.
                                    e. 24  VDC   constant  current power supply  1 No
                                    f.
Instruction Manual  1  Copy

IPC-030                EXPERIMENTAL SET UP OF V/F  CONVERTER                     

                                    The setup consists of :
                                    a. Frequency to voltage converter 
                                        Input   :  0-50  Hz
                                        Out put  : 0 –230  V
                                    b. Driver card 1 No  
                                    c. Voltmeter  1 No
                                    d. Frequency meter  1 No
                                    e. 24  VDc constant current power supply  1 No
                                    f. Instruction Manual 1 Copy

IPC-031                EXPERIMENTAL SETUP OF E/P  CONVERTER                     

                                    The setup consists of :
                                    a. Voltage to pressure converter 1  No
                                        Input   :  0-5  Volts 
                                       Out put :  3 –15 psi
                                    b. Air filter regulator  1 No
                                    c. Voltage source 1 No
                                    d. Digital panel indicator  1 No
                                    e. 24 V constant current D. C. power supply 1 No
                                    f. Instruction Manual 1 Copy

IPC-032                 EXPERIMENTAL SETUP OF P/E  CONVERTER                     

                                       The setup consists of :
a.                  Pressure to voltage converter  1 No
b.                  Air filter regulator 1 No
c.                  Digital panel indicator  1 No
d.                  24 V. D. C. constant current power supply 1  No.
e.                  Instruction Manual 1 Copy

IPC-033       SIMULATOR

It contains the simulation of four control loop namely, Flow, Level, Pressure & Temperature Control loops. All actions of P , P+1,  P+D  &  P + I + D  can be studied. All graphs, input & output levels, bar graphs are displayed on color monitor.  Set points can be changed. Values of  P. I. & D also changed & its effect on output can be observed on monitor.

Computer  : Pentium III with keyboard & color monitor.