IPC-001 CALIBRATION OF VENTURIMETER, ORIFICEMETER &
ROTAMETER
The
Setup Consists of :
a. Orificemeter : 1“ size with two G.M. Clocks.
b. Venturimeter : 1“ size with two G.M. Clocks.
c. Rotameter : 1“ size with 4.2 - 42 LPM.
d. Water Sump : 150 Ltr Capacity for close circuit system.
e. Measuring Tank : 300 x 300
x 450 mm size with drain valve &
gauge glass fittings.
f. Manometer : 1 mtr. height differential manometer without mercury.
g. Water pump : ½ HP for water circulation.
h. Instruction Manual : 1 Copy.
ICP-002 MEASUREMENT OF LEVEL BY AIR PURGE METHOD.
The setup consists of :
a. Air Purging Valve : ¼
“ BSP.
b. Manometer : 0.3 mtr. height.
c. Water tank of glass fitted in M.S. Casing.
d. Copper Tubing.
The whole unit is
mounted on sturdy M.S. Frame.
IPC-003 DETERMINATION OF TIME CONSTANT OF
THERMOMETER.
This setup consists of :
a. Digital Temperature Indicator with thermocouple.
b. Mercury filled dial thermometer.
c. Vapour pressure thermometer.
d. Electric sergri with pot.
e. Ice pot.
f. Instruction Manual : 1 Copy
IPC-004 DETERMINATION OF TIME CONSTANT OF MANOMETER
The
setup consists of :
a. Three manometers of different tubes &
different height with different
manometric fluid in each.
b. M.S. Structure with board for mounting of
three manometers.
c. Air pressure regulator : 1 No.
d. Instruction Manual : 1 Copy.
*
Service Required *
Constant
air supply of compressor @ 1 CFM & pressure @ 2 - 3 Kg/Cm2.
IPC-005 CALIBRATION OF BIMETALLIC THERMOMETER
The
Setup consists of :
a. Bimetallic Thermometer : 0 - 100 oC.
b. Constant Temperature bath with electrically
heating element.
c. Ice pot : 1 No.
d. Glass Thermometer : 1 No.
e. Instruction Manual : 1 Copy.
IPC-006 THERMOCOUPLE CALIBRATION TEST RIG
The
setup consists of :
a. Three different types of thermocouples, i.e. CR/AL, Cu-Constant
& Fe-Constant.
b. Constant temperature bath with heating element for hot junction.
c. Glass Thermometer : 1 No.
d. Instruction Manual : 1 No.
IPC-007 DEAD WEIGHT PRESSURE GAUGE TESTER
Range available : 0 - 30
Kg/Cm2 , 40 Kg/Cm2 , 60 Kg/Cm2.
Tester provided with
a gauge connector of ½ “ BSP of complete with one
set of weights in a storage box.
One
dust cover, spanner & one set of spare seals.
IPC-008 DEAD WEIGHT VACUUM GAUGE TESTER
Range : 0 - 740 mm of
Hg.
Tester provided with one
set of weights a storage box, gauge connector of ½
“ BSP One dust cover,
Instruction Manual one Pointer Puller, a adapter of
M20 x ¼”, ½ “ & 3/8” BSP, four spanner & one set of spare seals.
IPC-009 DIGITAL PH METER
The PH meter with test
probes, stand & breaker.
IPC-010 PERFORMANCE OF PNEUMATIC PI CONTROLLER.
The Setup Consists of :
A. Control Panel
a. Pneumatic
PI Controller :
Input : 0
- 10 Kg/Cm2.
Output : 0.2
- 1.2 Kg/Cm2.
Air Supply : 2
Kg/Cm2.
Mounting : Panel
Mounting.
b. Air Filter Regulator :
Input : 0
- 10 Kg/Cm2.
Output : 0.2
- 1.2 Kg/Cm2.
Filter : Bronze.
B. Final Control Element :
a. Pneumatically Actuated Diaphragm
Control Valve :
Size : 15 mm.
Action : Air
to Open.
Seat &
Plug : SS-316.
Qty. : 1 No.
b. Air Vessel :
Capacity : 20 Ltr.
Design
Pressure : 30 Kg/Cm2.
Instruction
Manual : 1 Copy
*
Service Required *
Constant
air @ 6 CFM & pressure @ 4 Kg/Cm2.
IPC-011 CHARACTERISTICS OF CONTROL VALVE.
( Equal & Linear
Percentage )
The Setup Consists of :
a. Pneumatically actuated diaphragm Control valve :
Size : 25 mm.
Action : Air
to Open.
Seat & Plug :
SS-316
Type : Equal Percentage : 1 No.
Linear
Percentage : 1 No.
b. Air Filter Regulator :
Input : 0
- 10 Kg/Cm2.
Output : 0.2
- 1.2 Kg/Cm2.
Filter : Bronze.
c. Measuring Tank :
Size : 300 x 300 x 450 mm with drain valve & gauge
glass fittings & a scale .
d. Supply Tank : Capacity : 150 Ltr with drain plug.
e. Water Pump : Capacity : ½” HP Single
Phase for water circulation
f. Instruction Manual : 1 Copy.
* Service Required *
Constant air @ 6 CFM & pressure @ 2 Kg/Cm2.
IPC-012 COMPUTERISED PH CONTROL SYSTEM.
The
Setup consists of :
A. Control Panel :
a. Computer : Pentium
with 8 MB RAM.
: 1.44 MB FDD.
: 101 Keys Keyboard.
: Super VGA color Monitor.
b. ADC Card : 1
No.
c. DAC Card : 1
No.
d. I/P Converter :
Input
: 4 - 20 mA.
Output : 0.2 - 1 Kg/ Cm2.
e. Allarm Annunciator :
Built to Computer.
f. Hooter : Built
to Computer.
g. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0.2 - 1.2 Kg/Cm2.
h. Control Panel :
It is fabricated from 16
gauge CRC sheet & well epoxy coated. All the above
instruments & wring will be mounted on panel. All the connections & wring will be
inside the panel. Necessary switches,
indicators are mounted on the panel.
B. Control Software :
A powerful control
software Window 98 Based for PH control.
On/Off control, proportional control, proportional plus integral
control, proportional plus integral plus derivative are done by software.
Simulating various
patterns of process variables & studying the controller response.
C. PH Transmission & Final Control Element :
a. Electronic PH Transmitter :
Input : From test probes.
Output : 4 - 20 mA.
b. Pneumatically Actuated Diaphragm
Control Valve.
Size : 15 mm.
Action : Air to Open.
Seat &
Plug : SS-316
Type : Linear Percentage.
c. Rotameter : 1
- 11 LPM for water.
d. Chemical Tank : 100
Ltr.
capacity.
e. Instruction Manual : 1
Copy
IPC-013
TWO TANK SYSTEM
A. INTERACTING SYSTEM.
The Unit Consists of :
a. Water Tank : 250 x 300 600
mm - 1 Nos.
b. Water Sump : 250 x 300 x 600
mm - 1 No.
c. Water Pump : Capacity : ½ H. P. for water circulation.
d. Strong iron stand for supporting the
equipment.
e. Above two tanks are mounted in such a
manner that system will be intractor.
f. Gauge glass fitting scale with drain
valve will be provided to each
tank.
g. Instruction Manual : 1 Copy.
B. NON-INTERACTING SYSTEM
Same as above ( A ), but two tanks
are mounted in such a manner that system will be Non-Interaction.
IPC-014 CLOSED LOOP FLOW CONTROL SYSTEM
The setup consists of :
A. Control Panel :
a. PID Controller : (
Electronic )
Input : 4 - 20 mA.
Output : 4 - 20 mA.
Display : 3.5 Digit.
Proportional
Band : 2 - 500 %.
Integral
Action : 0.05
- 50 R/min.
Derivative
Action : 0.01 - 10 Min.
b. I/P Converter :
Input
: 4 - 20 mA.
Output : 0.2 - 1 Kg/ Cm2.
c. Alarm Annunciator :
4 Window.
d. Hooter : 1 No.
e. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0.2 - 1.2 Kg/Cm2.
f. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be
inside the panel. Necessary switches,
indicators are mounted on
the panel.
B. Flow Transmission & Final Control Element :
a. Flow
Transmitter ( Wheel Type Electronic )
Range : 4.2
- 42 LPM.
Output : 4
- 20 mA.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
to Open.
Seat & Plug : SS-316.
Type : Linear Percentage : 1 No.
c. Rotameter :
Range : 4.2
- 42 LPM.
Service : Water.
d. Collecting Tank :
Size : 300 x 300 x 450 mm with drain valve & gauge
glass fittings & a scale .
e. Water Sump : 150 Ltr . Capacity with drain plug
f. Water Pump : Capacity : ½” HP Single Phase for water circulation
g. Instruction Manual : 1 Copy.
*
Service Required * Constant
air @ 6 CFM & pressure @ 2 Kg/Cm2.
IPC-015 CLOSED LOOP LEVEL CONTROL SYSTEM
The setup consists of :
A. Control Panel :
a. PID Controller : (
Electronic )
Input : 4 - 20 mA.
Output : 4 - 20 mA.
Display : 3.5 Digit.
Proportional
Band : 2 - 500 %.
Integral
Action : 0.05
- 50 R/min.
Derivative
Action : 0.01 - 10 Min.
b. I/P Converter :
Input
: 4 - 20 mA.
Output : 0.2 - 1 Kg/ Cm2.
c. Alarm Annunciator :
4 Window.
d. Hooter : 1 No.
e. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0.2 - 1.2 Kg/Cm2.
f. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be
inside the panel. Necessary switches,
indicators are mounted on
the panel.
B. Level Transmission & Final Control Element :
a. Electronic
Liquid Level Transmitter :
Range : 0
- 1000 mm of WC
Output : 4
- 20 mA.
Supply : 24
V DC.
Mounting : Field
mounting type.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
to Open.
Seat & Plug : SS-316
Type : Linear Percentage : 1 No.
c. Rotameter :
Range : 4.2
- 42 LPM.
Service : Water.
d. Liquid Level Tank : 90 Ltr. capacity with
overflow arrangement, drain valve gauge fittings & a scale
e Water Sump : 150 Ltr . Capacity with drain plug.
e. Water Pump : Capacity : ½” HP Single Phase for water circulation
f. Instruction Manual : 1 Copy.
*
Service Required * Constant
air @ 6 CFM & pressure @ 3 Kg/Cm2.
IPC-016
CLOSED LOOP PRESSURE CONTROL SYSTEM
The setup consists of :
A. Control Panel :
a. PID Controller : (
Electronic )
Input : 4 - 20 mA.
Output : 4 - 20 mA.
Display : 3.5 Digit.
Proportional
Band : 2 - 500 %.
Integral
Action : 0.05
- 50 R/min.
Derivative
Action : 0.01 - 10 Min.
b. I/P Converter :
Input
: 4 - 20 mA.
Output : 0.2 - 1 Kg/ Cm2.
c. Alarm Annunciator : 4 Window.
d. Hooter : 1 No.
e. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0 - 2 Kg/Cm2.
f. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be
inside the panel. Necessary switches,
indicators are mounted on
the panel.
B. Pressure Transmission & Final Control Element :
a. Electronic
Pressure Transmitter :
Range : 0
- 5 Kg/Cm2.
Output : 4
- 20 mA.
Supply : 24
V DC.
Mounting : Field
mounting type.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
to Open.
Seat & Plug : SS-316.
Type : Linear Percentage : 1 No.
c. Air Tank : 2 Nos. with
interconnecting valve pressure gauges mounted
on the tanks.
d. Air Compressor : 2 HP, 3 Phase motion & Air Tank Cap. 100 Ltr.
e. Instruction Manual : 1 Copy.
IPC-017 CLOSED LOOP TEMPERATURE CONTROL SYSTEM
The setup consists of :
A. Control Panel :
a. PID Controller : (
Electronic )
Input : 4 - 20 mA.
Output : 4 - 20 mA.
Display : 3.5 Digit.
Proportional
Band : 2 - 500 %.
Integral
Action : 0.05
- 50 R/min.
Derivative
Action : 0.01 - 10 Min.
b. I/P Converter :
Input
: 4 - 20 mA.
Output : 0 - 2 Kg/ Cm2.
c. Alarm Annunciator :
4 Window.
d. Hooter : 1 No.
e. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0 - 2 Kg/Cm2.
f. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be inside
the panel. Necessary switches,
indicators are mounted on
the panel.
B. Temperature Transmission & Final Control Element :
a. Temperature
Transmitter :
Input : From
RTD
Output : 4
- 20 mA.
Supply : 24
V DC.
Mounting : Field
mounting type.
b. Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action1 : Air
to Open.
Seat & Plug :
SS-316.
Type :
Linear Percentage : 1 No.
c. Rotameter :
Range : 1.1
- 11 LPM.
Service :
Water.
d. Heater Exchanger : Shell & Tube Type.
Capacity :
150
Kg/hr.
e Water Sump :
100 Ltr . Capacity with drain plug &
4 Kw heater fitted to
tank for hot water.
e. Water Pump : Capacity : ½” HP Single Phase for hot water circulation
f. Instruction Manual : 1 Copy.
*
Service Required *
Constant
air @ 6 CFM & pressure @ 2 Kg/Cm2.
Cold
water, @ 20 Ltr./min ( Min )
IPC-018 COMPUTERISED CLOSED LOOP FLOW CONTROL
SYSTEM
The
Setup consists of :
A. Control Panel :
a. Computer : Pentium
with 8 MB RAM
: 1.44 MB FDD.
: 101 Keys Keyboard.
: Super VGA color Monitor.
b. ADC Card
: 1
No.
c. DAC Card
: 1 No.
d. I/P Converter :
Input : 4 - 20 mA.
Output : 0.2 -
1 Kg/ Cm2.
e. Alarm Annunciator :
Built to Computer.
f. Hooter : Built
to Computer.
g. Air Filter Regulator :
Input : 0 - 10
Kg/Cm2.
Output : 0.2 -
1.2 Kg/Cm2.
h. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be
inside the panel. Necessary switches,
indicators are mounted on
the panel.
B. Control Software :
A powerful control
software Window 98 Based for flow control system.
On/Off
control, proportional control, proportional plus integral
control, proportional plus integral plus derivative control are done by
software.
Simulating
various patterns of process variables & studying the controller response.
C. Flow Transmission & Final Control Element :
a. Flow
Transmitter ( Wheel Type Electronic )
Range : 4.2
- 42 LPM.
Output : 4
- 20 mA.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
Open.
Seat & Plug : SS-316.
Type : Linear Percentage : 1 No.
c. Rotameter :
Range : 4.2
- 42 LPM.
Service : Water.
d. Collecting Tank : Size : 300 x 300 x 450 mm with drain valve & gauge
glass fittings
& a scale .
e. Water Sump : 150 Ltr . Capacity with drain plug
f. Water Pump : Capacity : ½” HP Single Phase for water circulation
g. Instruction Manual : 1 Copy.
*
Service Required * Constant
air @ 6 CFM & pressure @ 3 Kg/Cm2.
IPC-019 COMPUTERISED CLOSED LOOP LEVEL CONTROL SYSTEM
The
Setup consists of :
A. Control Panel :
a.
Computer : Pentium
with 8 MB RAM.
: 1.44 MB FDD.
: 101 Keys Keyboard.
: Super VGA color Monitor.
b. ADC Card
: 1
No.
c. DAC Card : 1
No.
d. I/P Converter : Input : 4 - 20 mA.
Output :
0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator : Built to Computer.
f. Hooter :
Built
to Computer.
g. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0 - 2 Kg/Cm2.
h. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy
coated.
All the above instruments & wring will be mounted on panel.
All the
connections & wring will be
inside the panel. Necessary switches,
indicators are
mounted on the panel.
B. Control Software :
A powerful control
software Window 98 Based for level control system.
On/Off control, proportional control, proportional plus integral
control, proportional plus integral plus derivative control are done by
software.
Simulating
various patterns of process variables & studying the controller response.
C. Level Transmission & Final Control Element :
a. Level
Transmitter :
Range : 0
- 1000 mm of WC
Output : 4
- 20 mA.
Supply : 24
V DC.
Mounting : Field
mounting type.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
Open.
Seat & Plug : SS-316.
Type : Linear Percentage : 1 No.
c. Rotameter :
Range : 4.2
- 42 LPM.
Service : Water.
d. Liquid Level Tank : 90 Ltr. capacity with
overflow arrangement, drain valve gauge fittings & a scale
e Water Sump : 150 Ltr . Capacity with drain plug.
Capacity : ½” HP Single Phase for water circulation
f. Instruction Manual : 1 Copy.
*
Service Required *
Constant
air @ 6 CFM & pressure @ 3 Kg/Cm2.
IPC-020 COMPUTERISED CLOSED LOOP PRESSURE CONTROL
SYSTEM.
The
Setup consists of :
A. Control Panel :
a.
Computer : Pentium
with 8 MB RAM.
: 1.44 MB FDD.
: 101 Keys Keyboard.
: Super VGA color Monitor.
b. ADC Card
: 1 No.
c. DAC Card
: 1
No.
d. I/P Converter :
Input : 4 - 20 mA.
Output :
0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator : Built to Computer
f. Hooter : Built
to Computer
g. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0 - 2 Kg/Cm2.
h. Control Panel : It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be inside
the panel. Necessary switches, indicators
are mounted on
the panel.
B. Control Software :
A powerful control
software Window 98 Based for pressure
control system. On/Off control,
proportional control, proportional plus integral control, proportional plus
integral plus derivative control are done by software.
Simulating
various patterns of process variables & studying the controller response.
C. Pressure Transmission & Final Control Element :
a. Pressure
Transmitter :
Range : 0
- 5 Kg/Cm2.
Output : 4
- 20 mA.
Supply : 24
V DC.
Mounting : Field
mounting type.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
to Open.
Seat & Plug : SS-316.
Type : Linear Percentage : 1 No.
c. Air Tank : 2 Nos. with
interconnecting valve pressure gauges mounted on the tanks.
d. Air Compressor : 2 HP, 3 Phase motion & Air Tank Cap. 100 Ltr.
e. Instruction Manual : 1 Copy.
*
Service Required * Constant
air @ 6 CFM & pressure @ 3 Kg/Cm2.
IPC-021 COMPUTERISED CLOSED LOOP TEMPERATURE CONTROL
SYSTEM.
The
Setup consists of :
A. Control Panel :
a. Computer :
Pentium
with 8 MB RAM.
: 1.44 MB FDD.
: 101 Keys Keyboard.
: Super VGA color Monitor.
b. ADC Card : 1
No.
c. DAC Card : 1
No.
d. I/P Converter :
Input
: 4 - 20 mA.
Output : 0.2 - 1 Kg/ Cm2.
e. Alarm Annunciator :
Built to Computer.
f. Hooter : Built
to Computer.
g. Air Filter Regulator :
Input : 0 - 10 Kg/Cm2.
Output : 0 - 2 Kg/Cm2.
h. Control Panel :
It is fabricated from 16
gauge CRC sheet & well epoxy coated.
All the above instruments & wring will be mounted on panel. All the connections
& wring will be inside
the panel. Necessary switches,
indicators are mounted on
the panel.
B. Control Software :
A powerful control
software Window 98 Based for Temperature control.
On/Off control, proportional control, proportional plus integral
control, proportional plus integral plus derivative control are done by
software.
Simulating various
patterns of process variables & studying the controller response.
C. Temperature Transmission & Final Control Element :
a. Temperature
Transmitter :
Input : From
RTD
Output : 4
- 20 mA.
Supply : 24
V DC.
Mounting : Field
mounting type.
b Pneumatically actuated diaphragm Control valve :
Size : 15 mm.
Action : Air
to Open.
Seat & Plug : SS-316.
Type : Linear Percentage : 1 No.
c. Rotameter :
Range : 1.1
- 11 LPM.
Service : Water.
d. Heater Exchanger : Shell & Tube Type.
Capacity : 150
Kg/hr.
e Water Sump : 100 Ltr . Capacity with drain plug &
4 Kw heater fitted to
tank for hot water.
e. Water Pump : Capacity : ½” HP Single Phase for hot water circulation
f. Instruction Manual : 1 Copy.
*
Service Required *
Constant
air @ 6 CFM & pressure @ 2 Kg/Cm2. Cold
water, @ 20 Ltr./min ( Min )
IPC-022 COMPUTERSIED RATIO CONTROL SYSTEM.
( Based On Flow )
The System Consists of :
a. Computer : Pentuim III 1.66 MHz speed with 1.44 MB FDD, Keyboard, & Colour Monitor.
b. Software : A Powerful software for ratio control system with PID
controller its P,I, P+I, P+D, & PID actions. Dataaquision for the on-line process.
c. Transmitters : Flow
Transmitters : 2 Nos.
Output : 4 - 20 mA.
Supply : 24 V DC.
Range : 0 - 500 mm of wc.
d. ADC & DAC Card : 2 Nos. in built in PC.
e. Level Tank : 1 No.
f. I/P Converter : 1 No.
Input : 4 - 20 mA
Output : 0.2 - 1 Kg/Cm2 .
g. Control Valve :
Diaphragm Actuated : 1
No.
Control Valve :
Line Size : ½ “
Pressure : 0.2 - 1 Kg/Cm2.
Action : Air to Open.
h. Alarm Annunicator : Built In PC
I. Hooter : Built in PC.
j. Air Filter Cum Regulator : 1 No.
* Service Required *
* 230 V AC Supply.
* Air at the range of 2 Kg/Cm2
constantly.
OPTIONAL :
i. Printer : EPSON LQ-1070+
IPC-023 COMPUTERSIED SPLIT RANGE CONTROL SYSTEM.
( Based On Temperature )
The System Consists of :
a. Computer : Pentuim 1.66 MHz
speed with 1.2 MB FDD, Keyboard, &
Colour Monitor.
b. Software : A Powerful software for Split Range control system
which is highly
sophisticated & can be handle by any person. It includes
all action of PID
controller graphic for set point controller output &
process variable. Bar graph
shows
columns for PV, CO, Error, Percentage Deviation & set point limits.
c. Temperature Transmitters: 3 Nos.
Output : 4 - 20 mA.
Supply : 24 V DC.
Range : 0 - 200 oC.
Input : From PT-100 Sensor.
d. ADC & DAC Card : 2 Nos. in built in PC.
e. I/P Converter : 1 No.
Input : 4 - 20 mA
Output : 0.2 - 1 Kg/Cm2
f. Control Valve :
Diaphragm Actuated : 1
No.
Control Valve :
Line Size : ½ “
Pressure : 0.2 - 1 Kg/Cm2.
Action : Air to Open.
g. Jacketed Vessel : 1 No.
Jacketed Vessel provided with
stirrer & fitted with
two transmitters
& one
control valve.
* Service Required *
* 230 V AC Supply.
* Air at the range of 2 Kg/Cm2
constantly.
OPTIONAL :
i. Printer : EPSON LQ-1070+
IPC-024 COMPUTERSIED CASCADE CONTROL SYSTEM.
( Based On Level & Flow )
The System Consists of :
a. Computer : Pentuim 1.66 MHz
speed with 1.2 MB FDD, Keyboard, & Colour Monitor.
b. Software : A Powerful software for cascade control system with PID
controller its P,I, P+I, P+D, & PID actions. Dataquision for the on-line process.
c. Flow Transmitter :
Output : 4 - 20 mA.
Supply : 24 V DC.
Range : 0 - 500 mm of wc.
d. Level Transmitter :
Output : 4 - 20 mA.
Supply : 24 V DC.
Range : 0 - 500 mm of wc.
e. ADC & DAC Card : 2 Nos. in built in PC.
f. Level Tank : 1 No.
g. I/P Converter : 1 No.
Input
: 4 - 20 mA
Output : 0.2 - 1 Kg/Cm2 .
h. Control Valve :
Diaphragm Actuated : 1
No.
Control Valve :
Line Size : ½ “
Pressure : 0.2 - 1 Kg/Cm2.
Action : Air to Open.
i. Alarm Annunicator : Built In PC
j. Hooter : Built in PC.
k. Air Filter Cum Regulator : 1 No.
* Service Required *
* 230 V AC Supply.
* Air at the range of 2 Kg/Cm2 constantly.
OPTIONAL :
i. Printer : EPSON LQ-1070+
IPC-025
CALIBRATION
OF PNEUMATIC DP TRANSMITTER
The unit consists of ,
a. Pneumatic DP Transmitter -
1 No.
Range :
2500 to 5000 mm of uc
Output
: 3 to
15 PSI
Input :
From differential pressure
Air Supply :
2 Kg/cm2
b. BP Apparatus to built the
pressure
c. Pressure gauge : 1 No.
d. Air Filter Regulator : 1 No.
e. Control Panel for : mounting of all above items.
IPC-026 CALIBRATION OF PNEUMATIC DP
TRANSMITTER
The unit consists of ,
a. Pneumatic DP Transmitter
- 1 No.
Range : 2500 to 5000 mm of uc
Output :
3 to
15 PSI
Input : From differential pressure
Air Supply : 2 Kg/cm2
b. BP Apparatus to built the
pressure
c. Pressure gauge
: 1 No.
d. Air Filter Regulator
: 1 No.
e. Control Panel for
: mounting of all above items.
IPC-027 CALIBRATION
OF I/P CONVERTER
The
unit consist of ,
a. I/P Converter
: 1 No
Input : 4
to 20 mA.
Output :
2
to 1 kgl cm2 or 3 to 15 PSI
Supply : 24
V. D. C.
b. Digital Multimeter
: To measure
current of I/P converter
c.
4-20 mA. Current sourct : For 4 to 20
mA. Input to converter
d.
24 V. D. C. Power supply : 1 No.
e. Pressure Gauge :
o to 1
kg cm2 to measure output signal from converter.
f. Control Panel :
For
mounting all above instruments.
IPC-028 CALIBRATION
OF P/I CONVERTOR
The setup consists of
a.
Pressure to current converter
Input :
3 to 15
Out put : 4 mA
to 20 mA.
b. Air filter regulator 1 No
c. Digital current indicator 1 No
d. 24 V Dc constant current power supply 1 No
e. Instruction manual
1 No.
IPC-029 EXPERIMENTAL
SET UP OF V/F CONVERTER
The setup consists of :
a. Voltage to frequency converter
Input
: 0-230 V
Out put
: 0-50 Hz
b. Driver card
1 No.
c. Voltmeter
1 No
d. Frequency meter
1 No.
e. 24 VDC constant
current power supply 1 No
f. Instruction Manual
1 Copy
IPC-030 EXPERIMENTAL
SET UP OF V/F CONVERTER
The setup consists of :
a. Frequency to voltage converter
Input
: 0-50 Hz
Out
put : 0 –230 V
b. Driver card 1 No
c. Voltmeter 1
No
d. Frequency meter
1 No
e. 24 VDc
constant current power supply 1 No
f. Instruction Manual 1 Copy
IPC-031 EXPERIMENTAL
SETUP OF E/P CONVERTER
The setup consists of :
a. Voltage to pressure converter 1 No
Input
: 0-5 Volts
Out put : 3
–15 psi
b. Air filter regulator 1 No
c. Voltage source 1 No
d. Digital panel indicator 1 No
e. 24 V constant current D. C. power supply 1 No
f. Instruction Manual 1 Copy
IPC-032 EXPERIMENTAL
SETUP OF P/E CONVERTER
The setup consists of :
a. Pressure to voltage converter 1 No
b. Air filter regulator 1 No
c. Digital panel indicator 1 No
d. 24 V. D. C. constant current power supply 1 No.
e. Instruction Manual 1 Copy
IPC-033 SIMULATOR
It contains the simulation of four
control loop namely, Flow, Level, Pressure & Temperature Control loops. All
actions of P , P+1, P+D &
P + I + D can be studied. All
graphs, input & output levels, bar graphs are displayed on color monitor. Set points can be changed. Values of P. I. & D also changed & its effect
on output can be observed on monitor.
Computer :
Pentium III with keyboard & color monitor.
|