A. ABSORPTION.
MT-001 ABSORPTION IN BUBBLE COLUMN (Absorption of Co2)
The
arrangement is semi-continuos operation. The
rotameteres are precalibrated with Co2
& air respectively.
Co2 is
taken from a cylinder. The Co2 cylinder valve must
be constantly kept
warm by pouring water or by alternate
arrangement . Air supply can be
obtained from compressor
air line
or a blower suitable valves are provided to control
gas flow
rate.
MT-002 ABSORPTION IN PACKED COLUMN.
Rotameter
are used for air & Co2
respectively. Air supply is
obtained from the compressor & Co2 is derived from cylinder.
A mixing length is provided for Co2 & air
to mix thoroughly.
The column is of
glass with rasching packing.
The liquid is fed from overhead tank through a rotameter & the liquid level
controller ensures the
liquid in
the disc engaging section. Liquid is distributed by means of
distributor.
MT-003 ABSORPTION COUNTER CURRENT WITH
CHEMICAL REACTION
The set up consists of a still filled with benzene & the
column packed with copper gauge packing to provide separation
facility for
the benzene
from mono chlorobenzene.
The chlorine
concentration air stream
is varied & the calculated values
of reaction constant
plotted against chlorine concentration to classify
the order
of the reaction. The outlet gas stream is sampled
& analysed using an Orsat apparatus, the
chloride gas in caustic soda in order to determine the concentration.
The liquid is sampled & analysed by refractometer for mannochlorobenzene constant.
MT-004 FIXED BED ABSORBER.
The
unit consists of
a bed of activated carbon housed
in a chamber, with provision
for inlet of the feed gas & its exit.
Provision is made for reactivation of
bed by means of steam
heating. The absorption chamber will be
200 mm in dia. & (40 mm long).
MT-005 GAS ABSORPTION APPARATUS.
The set up consists of a glass column(coming)
of 75 mm dia. &
400 mm long (made in two sections), rotameters for
gas, air &
liquid, air compressor, control valves, pump for liquid, storing tank
etc. The unit is suitably mounted with
an operating platform.
MT-006 MASS TRANSFER WITH CHEMICAL REACTION.
The
experimental set up
is designed for mass transfer with chemical reaction
from gas phase to the liquid phase. The
gas liquid contact is facilitated in a glass column & arrangements are made for measuring the flow rates of each.
MT-007 WETTED WALL COLUMN.
Air is
supplied to the column at the bottom by means of a compressor. By pass
valve & control valve are used for
varying the air flow rate. The conditions of air at inlet to &
outlet from the column are measured by the wet & dry bulb
thermometers. Air flow rate is measured by
rotameter. Water inlet
& outlet temperatures are
measured by the thermometers.
B. DISTILLATION
:
MT-008 BATCH PLATE RECTIFICATION COLUMN.
The
unit consists of a column
containing 13 plates used for rectification as a batch process. The unit is designed to
separate most of the two component system &
is made up of stainless steel of AISI-304 grade. Sight glasses, sample clocks thermo wells at
suitable locations are provided. Arrangements are made
to measure the
temperatures at strategic
locations.
MT-009 BUBBLE CAP DISTILLATION COLUMN.
a. Distillation Column :
Material : SS-304.
Diameter : 110 mm
Seven Plates with one cap per plate.
b. Feed Tank
: Material - SS-304, Capacity : 20 Ltrs.
c. Feed Tray : Special Arrangement to change feed
either to fourth or fifth plate.
d. Flow Measurement :
Rotameter ( One each for
Feed, Water, reflux distillate & Bottom product )
e. Reboilers : Material SS-304
f. Condenser :
Type :
Shell & Tube
Material : SS - 304.
Area : 0.40 Sqm
g. Bottom Product Tank :
Material : SS - 304.
Capacity : 5 Ltrs.
h. Distillate Tank :
Material : SS - 304.
Capacity : 5 Ltrs.
i. Water Supply Tank :
Material : SS - 304.
Capacity : 5 Ltrs.
j. Water Pump : Tullu Make.
k. Reflux Drum
:
Material : Glass/ SS - 304.
Capacity : 2 Ltrs.
l. Temperature Indicator : Digital with Multi Channel
Indicator
m.
Sensors : R.T.D.
( P.T. 100, 11 Nos )
n. Power Consumption : 6.5
Kw.
distillation column used in a glass/steel column
with perforated
plates. The
feed mixture flow by
gravity through
a
rotameter & enters the column in the middle. Vapour is
generated in still by means of a electrical
heater. The reflux ratio is controlled by
operating the product & reflux value below the water cooled condenser.
MT-010 DISTILLATION AT TOTAL REFLUX
The unit
consists of a
packed column with ceramic rasching rings
or berl saddes. Four necked glass with a heating metal
is used as
a reboiler. This system is designed by
methnol water system. The vapour stream rich in
methnol flows up the column & is condensed in the condenser provided with copper coil in which cooling
water is circulated. The
flow rate of
cooling water can be
measured through rotameter
& that of the reflux by the rotameter. The temperature of
various stream can be measured. The
density of bottom
& reflux can
be measured by using
specific gravity or by the
method of refractive index.
MT-011 DISTILLATION UNDER VACCUM (DIFFERENTIAL
DISTILLATION TO VERIFY REYLEGH’S EQUATION):
The
experimental set up
consists of a distillation
still is surrounded still is constructed out of
mild steel. The
steel is surrounded by a steel jacket. The vapour coming from the steel are sucked by
means of vaccum
pump. only non
condensable gases go
to the pump
while the vapour
in condensed in the water called condenser. Water is
circulated through the condenser
coils by means of a pump
connected to a
pump. The bottom product from
the steel is discharged by means of the bottom drain point while the condensed vapour is discharge by
means of the drain.
MT-013 EQUILIBRIUM FLASH DISTILLATION
The
apparatus consists of an
overhead tank which contains
liquid under going distillation. The liquid from the tank is
metered through the rotameter & then goes inside the copper coil in the boiler. Steam condenses outside the coil. The liquid then enters the flash chamber after being throttled by a
valve. In the flash chamber the
liquid flashes into vapour partially.
The vapours are let to the condenser where they are condensed by water.
Condensed vapour are collected
& quantity measured. The enriched liquid at the bottom of the
chamber is collected & measured.
MT-014 FRACTIONAL AND RECTIFICATION COLUMN.
The
unit consists of :
a.
The
main column is of SS-316
with
perforated plates.
The column is packed with rashing rings.
b.
Gear
pump for feed
of the mixture
25 RPM capacity.
c.
Rotameter : 0 to 15 RPM capacity.
d.
Condenser : Is of
suitable capacity
with reflux divider.
MT-015 SIMPLE STEAM DISTILLATION.
The
equipment consists of jacketed vessel of mild steel construction
designed for simple distillation.The
vessel is equipped with a steam trap, steam
sparger, mercury valve,
pressure gauges, temperature indicator
& a copper
coil condenser. A glass collector
steam flow rate.
C. EXTRACTOR :
MT-016 LEACHING EXPERIMENT(SOLID LIQUID EXTRACTION)
The
soluble constituent from
a solid by means of solvent
can be extracted by leaching
process. The process can be adopted
either for the production of a concentrated
solution of valuable solid material or an insoluble solid such as pigment may be forced from a
soluble material with it is contained.
This unit consists of
i. Feed Tank of 25 Ltr of SS-304.
ii. SS-304 column of having diameter 3 ˝”
iii. Reboiler
iv. Condenser SS-304
v. Rotameter
vi. Other accessories like Digital Temperature
Indicator,
Control Valves of SS-304, Drain valve.
All
accessories mounted on M.S. Sturdy frame.
MT-017 LIQUID - LIQUID EXTRACTION.
The unit
consists of a
glass column fitted with rashing ring.
i. Two precalbracated rotameters.
ii. Two feed vessels for mixture & water.
iii. Sparger
The mixture & solvent can contacted counter
urrently then
extract & reffinate are analysed for purity.
MT-018 PACKED COLUMN EXTRACTION
The set
up consists of a metal column provided with rashing rings packing. The packing is adjusted in two sections with a liquid redistributor in the
middle. The column is provided with
liquid distributor at the bottom
& top. Overhead
collecting tanks are provided for water &
toluene with arrangement to arrange the flow rates through calibrated
rotameter & inverted
manometer. The composition of various streams
are measured by titillating
samples against standard sodium hydroxide solution.
MT-019 YORK - SCHEIBEL COLUMN.
This set
up is used to determine the overall height of a transfer unit
(Raffinate phase), overall height of a transfer unit
( Extract phase ), overall volumetric mass transfer
coefficient (Raffinate phase) & overall
mass transfer coefficient ( Extract phase ) by carrying out liquid-liquid
extraction in a york-scheibel column using the system acetic acid - toluene,
water.
The
set up is as shown, wherein there is contract
between the solvent & feed phases which results into extract & reffinate
steams. Rotameters precalibrated
for toluene acetic acid &
water respectively are provided.
The continuos & dispersed phase streams are metered
through the above
rotameter & are derived from separate glass containers. Each stage consists of
a woven wire mesh section &
a mixing section. A suitable glass
column section which can provide
for about 8-10
stages is provided. The impeller speed is set
to the desired value with the help
of veriable step-pulley drive. The centrally mounted shaft supporting the
impellers is driven with the help of suitable induction motor. Considering the case where
the dispersed phase flow is downwards while the continuos phase
flow is upwards, the dispersed phase is water while the continuos phase
is mixture of toluene & acetic acid.
In such a case the extract will
be collected from the top. While performing this experiment the following procedure is
adopted.
The
column is fitted
with the given toluene acetic acid
mixture. The rotameter readings for both the phase are
adjusted to prefixed
values (1.25 to 5 Revls).
The lower interface is adjusted to suitable
height with the help of stop clock at the reffinate
collection point. The first observation is taken after
two lines the mean residence time of the dispersed continuos phase
( depending on which is larger). The following measurements are done after allowing sufficient time (approx. 10
min) for steady state to be attained.
a. Flow rate
of extract.
b. Flow rate
of reffinate.
c. Density
of extract.
d. Density
of reffnate.
Density of feed is also determined using
hydrometer. The extract
& reffinate samples
are collected & analysied
for acetic acid by titillating with standard NaOH. Similarly
the acetic acid contain of feed
is determined. The procedure
is repeated for tow different speeds if agitation.
D. OTHER
ITEMS.
MT-020 DIFFUSION CO-EFFICIENT OF CCL IN AIR
SALT IN WATER
DETERMINATION
OF DIFFUSION CO-EFFICIENT (CCL, IN AIR)
The
experimental set up consists of glass U tube with a
capillary base. The U tube is immersed in water tank. In order
to carry out diffusion at different temperatures, water is circulated by means of pump
through a geyser. A scale is provided in front of the
capillary for measurement of fall liquid level. Fan is provided to blow a
gentle current of air over the
capillary box, at a rate controlled by
a butterfly valve. The tank temperature
& in turn the liquid temperature is measured by the thermometer.
MT-021 DIFFUSION IN STILL AIR.
This table mounted
set up is
used for measuring diffusion of carbon letrachoride in air & it’s
variation with temperature. A vaccum
pump is used for drawing a
gentle current of air over evaporating
basin. A heater is provided for
determining diffusion
coefficients at the different
temperature. The height of the
glass tube will be appox. 200
mm & dia. 10 mm.
The set up also consists
of temperature indicator, vermier calliperse, stop clock,
voltmeter, ammeter, electronic dimmer etc.
MT-022 ION EXCHANGER
This unit consists
of two columns packed with cation & anion
resins upto sutiable
height. One tank are provided for the supply of the Nacl solution & Ailkali solution.
One precalibrated rotameter is provided
to measure water flow rate.
A online direct reading
conductivity meter electricity operated is provided to
measure conductivity for inlet & outlet water.
SS tank of 60lit.capacity with a pump is
provided.
Features :
i. After giving calculated quantity of water
resines get exhausted. They can be raised after regeneration with small
quantity of Acetic Acid & Alkali.
ii. High
purity of water
at low cost since conductivity is proportions to dissolve solids, its measurement
is useful in determining quantity
of water, is
compared with distilled water.
MT-023 LIQUID - LIQUID EQUILIBRIUM
Liquid
extraction or solvent
is the separation of the
constitutes of a liquid solution by contact with another
insoluble liquid. If the substances constituting the original
solution distribute themselves differently between
the two liquid
phases certain degree
of separation results. Hence all
three components (at least to
some extent ) to which separation can be achieved
depends on the tenary liquid - liquid equilibrium. This experimental set up is designed to establish the ternary isotherms.
MT-024 MODELS OF PACKING & PLATES USED FOR
DISTILLATION
Plates : Sieve plate, Bubble cap.
Packing
: Raschig
ring, Lessing ring, Pall ring.
Berl
Saddles.
MT-025 MASS TRANSFER IN MECHANICALLY AGITATED
CONTRACTORS.
Agitation in any
liquid - liquid system is required for the following reasons :
1. Increase of
interfacial surface
area by dispersing one liquid
phase into another immiscible liquid.
2. Reduction of
diffusion resistance out-side dispersed drops
3. Increase of mass transfer within dispersed
drops
4. Further coalescence
& redispersion
of drops which
provides mixing effect.
This set up is designed to :
1. Experiment for
determining the
critical speed
of dispersion.
2. For dispersion of heavy liquid in light.
3. For dispersion of light liquid.
4. To determine the mass transfer between the two
phases with
respect
to the
types of
dispersion, digree of agitation
etc.
MT-026 SOLID DISSOLUTION
The equipment consists
of cylinder of benzoic acid
mounted on stainless steel rod
& driven by a motor through
a step down pulley
arrangement. The RPM of the cylinder
will be approx.
60 rev /
min. This is immersed in
an acquious solution of sodium hydroxide of known concentration so that the solid is below the surface of
2 - 3 cms. the beaker used will be 500 ml. capacity. The
solid dimensions are 30 mm dia.
& 60 mm. length. This cylinder can be prepared by pouring
moutlen with the shaft already heated
in the center of the mold in a vertical position.
MT-027 VAPOUR LIQUID EQUILIBRIUM (VLE APPARATUS)
The VLE apparatus is all glass system with provision for
measuring the temperature of both phases
at equilibrium. It is provided
with a suitable heating metal. The compositions of the equilibrium
mixtures can be measured by any
of the standard
techniques like refractive index or specific gravitates.